Related Products

GV2ME14

GV2ME14
Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals.

GVAE11

GVAE11
TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NC

ATV212HD37N4

ATV212HD37N4
37Kw/50Hp 380…480VAC 3Phase 50/60Hz.
Benefits
Centralised Technical Management
- Instant viewing of the energy consumption
- Detection of failures for quick intervention including belt breakage, pump running dry, phase failure and supply fault
- Preventative maintenance for reducing costs and optimising the equipment including fault alerts, operating times and more
- Connection to building supervision network using embedded protocols
User-friendliness
- Tools for installing, parametering and viewing the installation (remote graphic terminal in 6 languages, Multi-Loader, Bluetooth and SoMove Mobile)
- Compact size
- Simple maintenance
Protection
- Continuity of service assured
- Dedicated “Building” series functions (fire mode, register monitoring, mechanical protection function, etc.)
- Integrated EMC filter, antiharmonic technology (THDI ˜ 30%)
Applications
Ventilation:
- Less noise pollution (airdraulic noise, motor noise, etc.)
- Detection of transmission component breakage
- Smoke extraction: forced start with fault inhibition
- Automatic restart
- Allows register management
Heating and Air conditioning:
- Optimise control in fluid processing
- Use of PID controller (temperature, flow rate, pressure, etc.)
- Adjustable flow rates for better energy management
- Suppression of mechanical resonance
Pumping:
- Detection of underload/overload, pump running dry
- Multi-motor configuration
- Limitation of operating time at low speed
- Sleep/Wake function
- Pressure surge suppression for prolonging the life of the installation

ATV212HU15M3X

ATV212HU15M3X
1.5Kw/2.0Hp 200…240VAC 3Phase 50/60Hz.
Benefits
Centralised Technical Management
- Instant viewing of the energy consumption
- Detection of failures for quick intervention including belt breakage, pump running dry, phase failure and supply fault
- Preventative maintenance for reducing costs and optimising the equipment including fault alerts, operating times and more
- Connection to building supervision network using embedded protocols
User-friendliness
- Tools for installing, parametering and viewing the installation (remote graphic terminal in 6 languages, Multi-Loader, Bluetooth and SoMove Mobile)
- Compact size
- Simple maintenance
Protection
- Continuity of service assured
- Dedicated “Building” series functions (fire mode, register monitoring, mechanical protection function, etc.)
- Integrated EMC filter, antiharmonic technology (THDI ˜ 30%)
Applications
Ventilation:
- Less noise pollution (airdraulic noise, motor noise, etc.)
- Detection of transmission component breakage
- Smoke extraction: forced start with fault inhibition
- Automatic restart
- Allows register management
Heating and Air conditioning:
- Optimise control in fluid processing
- Use of PID controller (temperature, flow rate, pressure, etc.)
- Adjustable flow rates for better energy management
- Suppression of mechanical resonance
Pumping:
- Detection of underload/overload, pump running dry
- Multi-motor configuration
- Limitation of operating time at low speed
- Sleep/Wake function
- Pressure surge suppression for prolonging the life of the installation

GV2LE08

GV2LE08
Motor circuit breaker, TeSys GV2, 3P, 4 A, magnetic, toggle control, screw clamp terminals