Related Products

GVAD1001

GVAD1001
TeSys GV2 & GV3 – auxiliary contact – 1 NC + 1 NO (fault)

Robusta Contactors & Overload Relay

Robusta Contactors & Overload Relay
RANGE
robusTa Contactors
- Rating: 9A~2100A
- Poles: 3 & 4 Pole, control relays
Overload Relays
- Rating: 0.1A~ 1000A
FEATURES
- Superior functional aesthetics and advanced performance
- Common add-on accessories – front / side auxiliary contact block, pneumatic timer block, mechanical interlock & coil suppressor
- Overload relays auto / manual reset with built-in single phase protection
- High mechanical life achieved by optimum design and world class material
Contact Us also available on 


ATV212HU55M3X

ATV212HU55M3X
5.5Kw/7.5Hp 200…240VAC 3Phase 50/60Hz.
Benefits
Centralised Technical Management
- Instant viewing of the energy consumption
- Detection of failures for quick intervention including belt breakage, pump running dry, phase failure and supply fault
- Preventative maintenance for reducing costs and optimising the equipment including fault alerts, operating times and more
- Connection to building supervision network using embedded protocols
User-friendliness
- Tools for installing, parametering and viewing the installation (remote graphic terminal in 6 languages, Multi-Loader, Bluetooth and SoMove Mobile)
- Compact size
- Simple maintenance
Protection
- Continuity of service assured
- Dedicated “Building” series functions (fire mode, register monitoring, mechanical protection function, etc.)
- Integrated EMC filter, antiharmonic technology (THDI ˜ 30%)
Applications
Ventilation:
- Less noise pollution (airdraulic noise, motor noise, etc.)
- Detection of transmission component breakage
- Smoke extraction: forced start with fault inhibition
- Automatic restart
- Allows register management
Heating and Air conditioning:
- Optimise control in fluid processing
- Use of PID controller (temperature, flow rate, pressure, etc.)
- Adjustable flow rates for better energy management
- Suppression of mechanical resonance
Pumping:
- Detection of underload/overload, pump running dry
- Multi-motor configuration
- Limitation of operating time at low speed
- Sleep/Wake function
- Pressure surge suppression for prolonging the life of the installation

GVAE11

GVAE11
TeSys GV2 & GV3 – auxiliary contact – 1 NO + 1 NC

GV1G09

GV1G09
TeSys GV, top feed terminal block, for busbars, 3 P, for TeSys D and TeSys U