GV2AF3

GV2AF3
TeSys GV2 – Combination blocks – with contactor LC1D09…D38

Switch Disconnectors

Switch Disconnectors
RANGE
- Rating: 25A ~ 3150A, 415V, AC23A
- Poles: 2P, 3P, 4P & 6P
FEATURES
- Modular pole design – economical maintenance
- Available in open / sheet steel enclosure version
- Quick make & break mechanism, self cleaning contacts
- Compact construction
- Door interlock and padlock facility
- Suitable for isolation
- Telescopic shaft for depth adjustment
- Door defeat
- Provision for 2NO+2NC aux contacts
Contact Us also available on 


GV2LE10

GV2LE10
Motor circuit breaker, TeSys GV2, 3P, 6.3 A, magnetic, toggle control, screw clamp terminals

ATS22C25S6

ATS22C25S6
75Kw/132Kw 208…575VAC 3Phase 50/60Hz.
Benefits
Let your applications take the strain
- Integrates bypass and safety functions
- Reduces your operating costs
- Simplifies wiring
- Protects your electrical installation
- Saves space with a fully equipped product
Applications
- Pumps
- Fans
- Compressors

ATV320U15N4C

ATV320U15N4C
1.5Kw/2Hp 380…500VAC 3Phase 50/60Hz.
Benefits
Centralised Technical Management
- Instant viewing of the energy consumption
- Detection of failures for quick intervention including belt breakage, pump running dry, phase failure and supply fault
- Preventative maintenance for reducing costs and optimising the equipment including fault alerts, operating times and more
- Connection to building supervision network using embedded protocols
User-friendliness
- Tools for installing, parametering and viewing the installation (remote graphic terminal in 6 languages, Multi-Loader, Bluetooth and SoMove Mobile)
- Compact size
- Simple maintenance
Protection
- Continuity of service assured
- Dedicated “Building” series functions (fire mode, register monitoring, mechanical protection function, etc.)
- Integrated EMC filter, antiharmonic technology (THDI ˜ 30%)
Applications
Ventilation:
- Less noise pollution (airdraulic noise, motor noise, etc.)
- Detection of transmission component breakage
- Smoke extraction: forced start with fault inhibition
- Automatic restart
- Allows register management
Heating and Air conditioning:
- Optimise control in fluid processing
- Use of PID controller (temperature, flow rate, pressure, etc.)
- Adjustable flow rates for better energy management
- Suppression of mechanical resonance
Pumping:
- Detection of underload/overload, pump running dry
- Multi-motor configuration
- Limitation of operating time at low speed
- Sleep/Wake function
- Pressure surge suppression for prolonging the life of the installation
- Sub-categories: