Contact Us
13, 1st Street, Simplicio Cruz Compound, Barangay San Isidro, Paranaque City
+632 8526-4869 • 8252-1135 • 8252-1136 • 8352-6612 • 8535-5017
+632 8526-4870
Related Products

LADN22

LADN22
Auxiliary contact block, TeSys D, 2NO + 2NC, front mounting, screw clamp terminals

ATV320D15M3C

ATV320D15M3C
15Kw/20Hp 200…240VAC 3Phase 50/60Hz.
Benefits
Centralised Technical Management
- Instant viewing of the energy consumption
- Detection of failures for quick intervention including belt breakage, pump running dry, phase failure and supply fault
- Preventative maintenance for reducing costs and optimising the equipment including fault alerts, operating times and more
- Connection to building supervision network using embedded protocols
User-friendliness
- Tools for installing, parametering and viewing the installation (remote graphic terminal in 6 languages, Multi-Loader, Bluetooth and SoMove Mobile)
- Compact size
- Simple maintenance
Protection
- Continuity of service assured
- Dedicated “Building” series functions (fire mode, register monitoring, mechanical protection function, etc.)
- Integrated EMC filter, antiharmonic technology (THDI ˜ 30%)
Applications
Ventilation:
- Less noise pollution (airdraulic noise, motor noise, etc.)
- Detection of transmission component breakage
- Smoke extraction: forced start with fault inhibition
- Automatic restart
- Allows register management
Heating and Air conditioning:
- Optimise control in fluid processing
- Use of PID controller (temperature, flow rate, pressure, etc.)
- Adjustable flow rates for better energy management
- Suppression of mechanical resonance
Pumping:
- Detection of underload/overload, pump running dry
- Multi-motor configuration
- Limitation of operating time at low speed
- Sleep/Wake function
- Pressure surge suppression for prolonging the life of the installation
- Sub-categories:
- ATV320 Compact
- ATV320 Bookcase

ATV320U15M3C

ATV320U15M3C
1.5Kw/2Hp 200…240VAC 3Phase 50/60Hz.
Benefits
Centralised Technical Management
- Instant viewing of the energy consumption
- Detection of failures for quick intervention including belt breakage, pump running dry, phase failure and supply fault
- Preventative maintenance for reducing costs and optimising the equipment including fault alerts, operating times and more
- Connection to building supervision network using embedded protocols
User-friendliness
- Tools for installing, parametering and viewing the installation (remote graphic terminal in 6 languages, Multi-Loader, Bluetooth and SoMove Mobile)
- Compact size
- Simple maintenance
Protection
- Continuity of service assured
- Dedicated “Building” series functions (fire mode, register monitoring, mechanical protection function, etc.)
- Integrated EMC filter, antiharmonic technology (THDI ˜ 30%)
Applications
Ventilation:
- Less noise pollution (airdraulic noise, motor noise, etc.)
- Detection of transmission component breakage
- Smoke extraction: forced start with fault inhibition
- Automatic restart
- Allows register management
Heating and Air conditioning:
- Optimise control in fluid processing
- Use of PID controller (temperature, flow rate, pressure, etc.)
- Adjustable flow rates for better energy management
- Suppression of mechanical resonance
Pumping:
- Detection of underload/overload, pump running dry
- Multi-motor configuration
- Limitation of operating time at low speed
- Sleep/Wake function
- Pressure surge suppression for prolonging the life of the installation
- Sub-categories:
- ATV320 Compact
- ATV320 Bookcase

Moulded Case Circuit Breaker-DC Application

Moulded Case Circuit Breaker-DC Application
RANGE
- Rating: 16-800A
- Poles: 2P, 3P & 4P
FEATURES
- Breaking capacity upto 100KA
- Higher nominal voltage upto 1000VDC
- Suitable for DC application such as photovoltaic / UPS / battery / datacenter etc.
- DC short circuit tested by VDE
Contact Us also available on 


ATV212HU15N4

ATV212HU15N4
1.5Kw/2.0Hp 380…480VAC 3Phase 50/60Hz.
Benefits
Centralised Technical Management
- Instant viewing of the energy consumption
- Detection of failures for quick intervention including belt breakage, pump running dry, phase failure and supply fault
- Preventative maintenance for reducing costs and optimising the equipment including fault alerts, operating times and more
- Connection to building supervision network using embedded protocols
User-friendliness
- Tools for installing, parametering and viewing the installation (remote graphic terminal in 6 languages, Multi-Loader, Bluetooth and SoMove Mobile)
- Compact size
- Simple maintenance
Protection
- Continuity of service assured
- Dedicated “Building” series functions (fire mode, register monitoring, mechanical protection function, etc.)
- Integrated EMC filter, antiharmonic technology (THDI ˜ 30%)
Applications
Ventilation:
- Less noise pollution (airdraulic noise, motor noise, etc.)
- Detection of transmission component breakage
- Smoke extraction: forced start with fault inhibition
- Automatic restart
- Allows register management
Heating and Air conditioning:
- Optimise control in fluid processing
- Use of PID controller (temperature, flow rate, pressure, etc.)
- Adjustable flow rates for better energy management
- Suppression of mechanical resonance
Pumping:
- Detection of underload/overload, pump running dry
- Multi-motor configuration
- Limitation of operating time at low speed
- Sleep/Wake function
- Pressure surge suppression for prolonging the life of the installation
















